RAID Capacity Calculator

Raw versus usable capacity, overhead and fault tolerance for RAID 0, 1, 5, 6 and 10.

What does this calculator do?

RAID trades capacity for redundancy, and how much it costs depends on the level. This calculator takes the level, the drive count and the capacity per drive and returns the raw total, the nominal usable capacity, the capacity consumed by parity or mirroring, the efficiency as a percentage, the number of drive failures the array survives and the minimum drive count the level requires. It assumes identical drives. The figure it produces is nominal array capacity — the capacity a filesystem reports after formatting is always somewhat lower, and this tool does not model that. Units follow the standards exactly: kB, MB, GB and TB are powers of ten (1 GB = 10⁹ bytes) while KiB, MiB, GiB and TiB are powers of two (1 GiB = 2³⁰ bytes). The two ladders are never mixed, so "1 GB = 1024 MB" is not treated as a universal rule.

Formula

Each level reserves a different amount of the raw capacity, with S the size of one drive and N the drive count.

RAID 0  = N × S        (no redundancy)
RAID 1  = S            (simple mirror)
RAID 5  = (N − 1) × S  (one drive of parity)
RAID 6  = (N − 2) × S  (two drives of parity)
RAID 10 = (N ÷ 2) × S  (mirrored pairs, N even)

efficiency = usable ÷ raw × 100

How to use it

Pick the RAID level, then enter the number of drives and the capacity of one drive — all drives are assumed to be the same size, since an array built from mixed sizes is generally limited to the smallest member. Choose TB if you are reading a drive label (drive vendors use 10¹² bytes) or TiB if your figure came from an operating system that reports powers of two. RAID 5 needs at least 3 drives, RAID 6 at least 4, and RAID 10 an even number.

Worked example

Four 2 TB drives in RAID 5: raw capacity is 4 × 2 = 8 TB, one drive’s worth is spent on parity, so the nominal usable capacity is (4 − 1) × 2 = 6 TB. Efficiency is 75%, overhead is 2 TB, and the array survives 1 drive failure. The same four drives in RAID 6 would give 4 TB usable and survive 2 failures; in RAID 10, 4 TB usable.

Formula version1.0.0
FormulaRAID 0 = N × S (no redundancy) RAID 1 = S (simple mirror) RAID 5 = (N − 1) × S (one drive of parity) RAID 6 = (N − 2) × S (two drives of parity) RAID 10 = (N ÷ 2) × S (mirrored pairs, N even) efficiency = usable ÷ raw × 100
Precision4 decimals

Frequently asked questions

Why does my array show less space than this?

Three separate effects. Drive vendors count in TB (10¹² bytes) while many operating systems display TiB (2⁴⁰ bytes), which alone looks like a 9% loss at TB scale. Filesystem metadata, journals and inode tables consume more. Controllers may also reserve space. This calculator reports nominal array capacity before all of that.

Is RAID a backup?

No. RAID protects against drive failure only. It does not protect against deletion, ransomware, filesystem corruption, controller failure, fire or theft. You still need backups that are separate from the array.

How many failures does RAID 10 really survive?

Guaranteed, one — the loss of both drives in the same mirrored pair destroys the array. With luck it can survive one failure in each pair, but a design should never rely on which drives happen to fail.

Why does RAID 1 show only one drive of capacity?

This calculator models the simple mirror case, where every member holds the same data, so usable capacity equals the size of one drive regardless of how many mirrors you add. Extra members add redundancy and read performance, not space.